Triol TM-01-03 telemetry system The measuring system for monitoring parameters of an oil well and an electric submersible motor by using a downhole sensor.
Purpose: The Triol TM-01 is used for monitoring actual parameters, as listed below:
- Motor oil temperature near the stator winding of an electric submersible motor (ESM);
- Base oil temperature;
- Pressure of motor oil in ESM;
- Vibration of ESM along the X, Y or Z axes; and
- Insulation resistance of the circuit “AC-voltage oil transformer – submersible electric cable – ESM”.
Actual parameters are transmitted to the controller of a variable speed drive. The last one is used for controlling and protecting electric submersible pumps with electric submersible motors, made in compliance with GOST 18058 or other types of motors.
The Triol TM-01-03 telemetry system consists of:
is a ground measuring and computational center. This unit runs as follows: - measures insulation resistance;
- establishes connection with the submersible unit;
- receives and processes data from the submersible unit; and
- transmits them to a controller of a variable speed drive or an automatic control system.
is a downhole sensor. This sensor is fixed to an ESM, measures parameters and transmits data to the ground unit.
The Triol TM-01-03 telemetry system is used by:
- Rosneft oil company (Purneftegaz, Juganskneftegaz);
- TNK-BP oil company (Samotlorneftegaz);
- RITEK oil company (Volgogradneftegaz business enterprise); and
- OAO NGK Slavneft (Megionneftegaz).
The Triol TM-01-03 enables to detect and display parameters listed below:
|
ESM temperature
|
from 0°C to + 200°C ±1%;
|
|
Base oil temperature
|
from 0°C to + 150 °C ±1%;
|
|
Pressure of motor oil in ESM
|
from 0 atm to 400 atm ±1%
|
|
Acceleration amplitude at vibration along radial and axial directions in the area of ESM hanging up
|
from 0 m/s² to 50 m/s² ±5%
|
|
Insulation resistance of circuit “AC-voltage oil transformer – submersible electric cable – ESM” in ranges
|
from 10 kOhm to 1000 kOhm ±2%
from 1000 kOhm to 10000 kOhm ±5.0%
|
TMN-01-03 ground unit
|
Rated input voltage
|
220 V ±40%
|
|
Frequency of supply main
|
50/60 Hz ±2%
|
|
Maximal consumed power
|
40 W
|
|
Ambient temperature
|
from - 60°C to + 75 °C
|
|
Relative air humidity at temperature of +25 °C
|
100%
|
|
Maximal height above sea level
|
1000 m
|
|
Index of protection according to IEC 529:1989 (GOST 14254)
|
IP21 or higher
|
|
Mode of operation
|
continuous
|
|
Maximal overall dimensions
|
212mm x 240mm x 142mm
|
|
Maximal mass
|
6 kg
|
TMP-01-03 submersible unit
|
Ambient temperature
|
from 0°C to + 150°C
|
|
Ambient temperature (temperature sensor is placed in place of ESM hanging up):
|
from 0°C to + 200°C
|
|
Maximal pressure in area of ESM hanging up
|
400 atm
|
|
Depth of submergence
|
3500 m
|
|
Index of protection according to IEC 529:1989 (GOST 14254)
|
IP68 or higher
|
|
Mode of operation
|
continuous
|
|
Overall dimensions:
|
|
|
Maximal diameter
|
96 mm
|
|
Maximal length
|
655 mm
|
|
Maximal mass
|
22 kg
|

The Triol TM-01-03 telemetry system. A variety of adapters and intermediate flanges allows connecting the submersible unit of the Triol TM-01-03 to ESM of different types and dimensions.

TMP-01-03 submersible unit
|
|